head_banner

Products

  • UL3289 XLPE Hook-Up Wire | 150°C, 600V

    UL3289 XLPE Hook-Up Wire | 150°C, 600V

    Technical Specifications

    Parameter Details
    Standard Compliance UL 758, CSA AWM I A/B, RoHS Compliant
    Conductor Material Stranded Tinned or Bare Copper (30 AWG - 4/0 AWG)
    Insulation Type Irradiation Cross-Linked Polyethylene (XLPE/XLPO)
    Rated Voltage 600V AC / 750V DC
    Rated Temperature 150°C (302°F)
    Flame Rating VW-1, FT1 (Highly Flame Retardant)
  • UL3321 Crosslinked Polyolefin Wire | 150°C, 600V

    UL3321 Crosslinked Polyolefin Wire | 150°C, 600V

    Technical Specifications

    Parameter Details
    Standard Compliance UL 758, CSA AWM I A/B, RoHS Compliant
    Conductor Material Stranded Tinned Copper (30 AWG - 4/0 AWG)
    Insulation Type Irradiation Cross-Linked Polyethylene (XLPE)
    Rated Voltage 600V AC
    Rated Temp 150°C (302°F)
    Flame Rating VW-1, FT1 (Self-extinguishing)
  • UL3173 XLPE Hook-Up Wire | 125°C, 600V

    UL3173 XLPE Hook-Up Wire | 125°C, 600V

    Technical Specifications

    Parameter Details
    Standard Compliance UL 758, CSA AWM I A/B, RoHS Compliant
    Conductor Material Finely Stranded Tinned or Bare Copper (26 AWG - 10 AWG)
    Insulation Type Cross-Linked Polyethylene (XLPE)
    Rated Voltage 600 Volts AC
    Rated Temp 125°C (257°F)
    Flame Rating VW-1, FT1 (Self-extinguishing)
  • UL10267 XLPE Insulated Wire | 105°C, 2000VAC

    UL10267 XLPE Insulated Wire | 105°C, 2000VAC

    Technical Specifications

    Parameter Details
    Standard Compliance UL 758, UL 1581, RoHS/REACH Approved
    Conductor Material Stranded Tinned or Bare Copper (30 AWG - 10 AWG)
    Insulation Type Irradiation Cross-Linked Polyethylene (XLPE/XLPO)
    Rated Voltage 2000 Volts AC
    Rated Temperature 105°C (221°F)
    Flame Rating VW-1, FT1 (Self-extinguishing)
  • UL10198 PVC Insulated Hook-Up Wire | 105°C, 300VAC

    UL10198 PVC Insulated Hook-Up Wire | 105°C, 300VAC

    Technical Specifications

    Parameter Details
    Standard Compliance UL 758, UL 1581, CSA C22.2 No.210.2
    Conductor Material 30 AWG - 4/0 AWG (Tinned or Bare Copper)
    Insulation Material Extruded Heat-Resistant PVC
    Rated Voltage 300 Volts AC
    Rated Temp 105°C (221°F)
    Flame Rating Horizontal Flame / Optional VW-1
  • UL1283 PVC Hook-Up Wire | 105°C, 600V

    UL1283 PVC Hook-Up Wire | 105°C, 600V

    105ºC  600V PVC INSULATION  WIRE

    Rated temperature:105ºC

    Rated voltage:600V

    According to:UL subject 758,UL1581,CSA C22.2

    Solid or Stranded,tinned or bare copper conductor 8~2AWG

    PVC insulation.

    Passes UL VW-1 & CSA FT1 Vertical flame test

    Environmental testing pass RoHS

    The wire can use for the Internal wiring of appliances where exposed to oil at a temperature not exceeding (60°C or 80°C, whichever is applicable)

  • UL1032 PVC Hook-Up Wire | 90°C, 1000V

    UL1032 PVC Hook-Up Wire | 90°C, 1000V

    Technical Specifications

    Parameter Details
    Standard Compliance UL 758, UL 1581, CSA C22.2
    Conductor Material Solid or Stranded Tinned/Bare Copper (30 AWG - 4/0 AWG)
    Insulation Material Heavy-Duty Extruded PVC
    Rated Voltage 1000V AC / 1200V DC
    Rated Temp 90°C (194°F)
    Flame Rating VW-1, FT1 (Self-extinguishing)
  • UL11627 PVC Insulated Wire | 105°C, 2000VAC

    UL11627 PVC Insulated Wire | 105°C, 2000VAC

    105ºC 2000V AC PVC INSULATION WIRE.

    Rated temperature:105ºC

    Rated voltage:2000V AC

    According to:UL subject 758,UL1581

    Solid or Stranded,tinned or bare copper conductor 30AWG-2000Kcmil

    PVC insulation.

    Passes UL VW-1 & CSA FT1 Vertical flame test

    Uniform insulation thickness of wire to ensure easy stripping and cutting.

    Environmental testing pass RoHS

    Internal Wiring of Appliances

  • UL10269 PVC Insulated Wire

    UL10269 PVC Insulated Wire

    80ºC,90ºC,105ºC 1000V PVC INSULATION WIRE.

    Rated temperature:80ºC,90ºC,105ºC
    Rated voltage:1000V
    According to:UL subject 758,UL1581
    Solid or Stranded,tinned or bare copper conductor 30-2000kcmil
    PVC insulation.
    Passes UL VW-1 & CSA FT1 Vertical flame test
    Uniform insulation thickness of wire to ensure easy stripping and cutting.
    Environmental testing pass RoHS
    Ground strap lead wire for the internal wiring of electronic equipment
  • 60227 IEC 08 RV-90 PVC Wire

    60227 IEC 08 RV-90 PVC Wire

    PVC INSULATION WIRE

    Rated temperature:90ºC
    Rated voltage:300/500V
    According to:GB/T 5023.3
    Solid or Stranded, bare copper conductor 0.5-2.5MM2
    PVC insulation.
    Passes 18380.12 Test
    Environmental testing pass RoHS
    Use for general electric equipment internal wiring.
  • 60227 IEC 52 RVV PVC Flexible Cable

    60227 IEC 52 RVV PVC Flexible Cable

    PVC INSULATION WIRE

    Rated temperature:70ºC

    Rated voltage:300/300V

    According to:GB/T 5023.5

    Solid or Stranded, bare copper conductor 0.5-0.75MM2

    PVC insulation.PVC jaket

    Passes 18380.12 Test

    Environmental testing pass RoHS

    Suitable for indoor electrical instruments power sipply wire

  • 60227 IEC 53 RVV PVC Flexible Cable | 300/500V

    60227 IEC 53 RVV PVC Flexible Cable | 300/500V

    PVC INSULATION WIRE.

    Rated temperature:70ºC
    Rated voltage:300/500V
    According to:GB/T 5023.5
    Solid or Stranded, bare copper conductor 0.75-2.5MM2
    PVC insulation.PVC jaket
    Passes 18380.12 Test
    Environmental testing pass RoHS
    Suitable for indoor electrical instruments power sipply wire
95 Total